ยทservice-~r1formatio&n
Tech.Cust.Service
VS-2011 kl/tw/fm
Motorcycles R60/6 – R90 S
Group: 23
Subject: Tightening Torque of Driving Flange
Gentlemen:
Munich. May ’74
1/74 (119 M) e
To permit a higher torque to be transmitted here as well as
from the series commencement of the /6 models 1 the output
drive shaft/driving flange bevel ratio has been modified from
1:6 to 1:7.
The tightening torque is 20 + 2 mkp for the 1:7 bevel ratio
and 22 + 2 mkp for the 1:6 bevel ratio.
So that no confusion can occur during repair. a list of the
components concerned is given below:
Description
1:6 driving flange for
/5 models
1:7 driving flange for
/6 models
1:6 output drive shaft
assembly for /5 models
1:7 output drive shaft
for /6 models
sยท cerely yours,
BAYE SCHEM OTOREWN ERKE
tiengesellschaft
p i. V.
Scholz
Part Number
23 31 l 230 057
23 21 l 232 557
23 21 l 230 077
23 21 l 231 695