Service-InformationM otorcycle
Group:
ยฉBMW of N.A.
Service Department
61
General
Electrics
August, 1992
61 027 92
(2548)
For USA Only
Additional Ground Between Engine and Frame – RlOORM odels
Problem:
Production
Line Change:
Remedy:
ยท-
/
Grounding between the engine and frame is not always
reliable on silver-painted frames. This may lead to
ignition misfiring or insufficient alternator output.
Starting with VIN 0280227, a wire has been added from
the starter motor cover to the ignition control unit
mounting bracket.
Install a ground wire to all affected RIOORm odels with
a VIN prior to 0280227.
The ground wire is secured to the left starter motor cover
screw and the ignition control unit mounting bracket.